A thermostatic mixing valve blends cold water into the hot outlet so the tank can be stored hot while the taps stay safe. The Cash Acme HeatGuard HG110-D publishes the fullest data of the three here — 85 to 130°F adjustable, 0.5 GPM minimum flow, 14 GPM at a 50 psi drop and a 230 psi body. The Honeywell AM-1 reaches 145°F on the common variant, and the Watts LFMMV-M1 publishes the tightest accuracy at +/-3°F. All three are listed to ASSE 1017.

This is one of the few parts on this site that does two useful things at once. It removes the scald hazard that comes with a hot tank, and it increases the amount of usable hot water a tank of any given size delivers, because water stored at 140°F stretches further once it is blended down to 120°F at the fixture.

That second effect is the one nobody mentions and the reason a mixing valve belongs in a conversation about running out of hot water. It is cheaper than a bigger tank and it fits in an afternoon.

Quick picks

Tap any row to read the full assessment below, or go straight to Amazon from the right-hand column. We earn a commission on qualifying purchases at no extra cost to you.

Ranked picks with what each one is best for, our score and a link to check the current price on Amazon.
#ProductBest forPrice
1
A brass and steel valve assembly
Cash Acme HeatGuard HG110-DThe mixing valve whose spec sheet answers the questions that decide an install: 85 to 130°F adjustable, 0.5 GPM minimum flow, 14 GPM at a 50 psi drop, and a published 120 to 180°F hot supply window.
The fullest published data
Check price on Amazon

No live price feed on this site, so we show none. #ad

2
A brass and steel valve assembly
Honeywell AM-1 (AM101) mixing valveThe thermostatic mixing valve that lets you store water at 140°F for bacteria control and still deliver a safe temperature at the tap — adjustable from 70 to 145°F depending on variant.
Storing hot, delivering safe
Check price on Amazon

No live price feed on this site, so we show none. #ad

3
Pressure gauges on a pipework assembly
Watts LFMMV-M1The tightest published accuracy of the three: +/-3°F across a 0.5 to 12 GPM range, 80 to 120°F adjustable, in a union-connection body that can be isolated and pulled without cutting pipe.
Holding a tap temperature steady
Check price on Amazon

No live price feed on this site, so we show none. #ad

The picks in full

A brass and steel valve assembly

Pick 1 — The fullest published data

Cash Acme HeatGuard HG110-D

The mixing valve whose spec sheet answers the questions that decide an install: 85 to 130°F adjustable, 0.5 GPM minimum flow, 14 GPM at a 50 psi drop, and a published 120 to 180°F hot supply window.

Published specifications for the Cash Acme HeatGuard HG110-D
Adjustable outlet range85 - 130°F (29 - 54°C)
Factory set range115 - 120°F (46 - 49°C)
Hot supply temperature120 - 180°F (48.9 - 82.2°C)
Cold supply temperature39 - 80°F (3.9 - 26.7°C)
Minimum flow0.5 GPM
Maximum flow at 50 psi14 GPM
Maximum pressure230 psi
BodyLead-free DZR brass; stainless springs and inlet strainers; engineered polymer piston
Sizes and ends1/2 in, 3/4 in and 1 in in sweat, FNPT, MNPT, CPVC, PEX barb, cold expansion, SharkBite union and direct SharkBite
StandardsASSE 1017, ASSE 1069, ASSE 1070/ASME A112.1070/CSA B125.70, CSA B125.3, NSF/ANSI/CAN 61 and 372

What is good

  • Publishes the minimum flow rate, which is the figure that decides whether a low-flow lavatory still gets tempered water
  • 230 psi body rating is the highest of the three valves here
  • A locking adjustment resists being turned up past the setting after inspection
  • Nine end-connection styles, including push-fit, so it suits almost any existing pipe without adapters
  • Triple-listed to ASSE 1017, 1069 and 1070, so one valve covers the common residential applications

What is not

  • Maximum outlet setting is 130°F, so it cannot be used to deliver very hot water to a commercial fixture
  • Needs a 120°F minimum hot supply to control properly — fit it to a tank set at 120 and it has nothing to mix with
  • The adjustment is a cap and a screwdriver, not a dial with numbers: you set it with a thermometer at the tap
  • Sold mostly through plumbing suppliers, so the part number matters more than the brand when you order

Skip it if: Skip it if you intend to leave the tank at 120°F. Every thermostatic mixing valve needs a hotter supply than its outlet setting, and this one publishes that window plainly: below a 120°F hot inlet it is outside its own stated range.

Check price on Amazon

No live price feed on this site, so we show none. #ad

Specifications above from Cash Acme HG110-D specification sheet, Rev 1.0 / 11-18-25 (PDF); Pace Supply listing, HG110-D 3/4 in sweat, item 24502; Cash Acme (Reliance Worldwide) thermostatic mixing valve range. We have not tested this unit ourselves.

A brass and steel valve assembly

Pick 2 — Storing hot, delivering safe

Honeywell AM-1 (AM101) mixing valve

The thermostatic mixing valve that lets you store water at 140°F for bacteria control and still deliver a safe temperature at the tap — adjustable from 70 to 145°F depending on variant.

Published specifications for the Honeywell AM-1 (AM101) mixing valve
Size3/4 in
BodyBrass, lead free
Pressure rating150 psi
Temperature rating212°F
Adjustable range70 - 145°F (variant dependent; 70 - 120°F and 70 - 180°F variants exist)
ConnectionsNPT, union CPVC, union press or PEX depending on variant

What is good

  • Lets you raise the tank set point for Legionella control without scalding anyone
  • Also increases usable hot water: hotter storage mixed down goes further
  • Multiple connection styles so it suits copper, CPVC, PEX or press
  • Anti-scald and anti-chill in one device

What is not

  • Several variants share the AM101 prefix with different temperature ranges — order the right one
  • It is one more device on the hot outlet that can fail closed
  • Needs a union or isolation to be serviceable

Skip it if: Skip it if you are not going to raise the tank temperature. Fitted to a tank set at 120°F it does almost nothing, and it adds a restriction and a failure point for no benefit.

Check price on Amazon

No live price feed on this site, so we show none. #ad

Specifications above from First Supply listing, Honeywell AM101-UCPVC-1LF/U; Granite Group listing, AM101-UP-1LF/U, 70-145F. We have not tested this unit ourselves.

Pressure gauges on a pipework assembly

Pick 3 — Holding a tap temperature steady

Watts LFMMV-M1

The tightest published accuracy of the three: +/-3°F across a 0.5 to 12 GPM range, 80 to 120°F adjustable, in a union-connection body that can be isolated and pulled without cutting pipe.

Published specifications for the Watts LFMMV-M1
Adjustable outlet range80 - 120°F
Temperature accuracy+/-3°F
Flow range0.5 - 12 GPM (refer to the Watts capacity chart)
Maximum pressure150 psi (10.55 bar)
ConstructionLead-free
End connectionsUnion threaded (-UT), solder (-US), PEX (-PEX), F1960 cold expansion (-CEF), CPVC (-CPVC), quick-connect (-QC) and press
StandardsASSE 1017, ASSE 1069, ASSE 1070, IAPMO cUPC
DesignDouble-throttle (M1)

What is good

  • A published +/-3°F accuracy figure, which neither of the other two valves here states
  • Union connections at both inlets mean it can be isolated and swapped without cutting into the pipework
  • Caps at 120°F, so it cannot be set to a scalding delivery temperature by a later occupant
  • Same ASSE 1017, 1069 and 1070 listings as the HeatGuard, from a brand already in most plumbing vans

What is not

  • 120°F is the ceiling, so it is no use where a fixture genuinely needs hotter water
  • Published flow figures disagree between Watts and its distributors (12 GPM on Watts' page, 13 and 20 GPM on some listings) — size from the Watts capacity chart
  • 150 psi body rating against 230 psi on the HeatGuard
  • Watts' own literature warns it is not a substitute for a fixture-level anti-scald device where code requires one

Skip it if: Skip it if you need the outlet above 120°F for a dishwasher or a commercial sink. The adjustment range stops at 120°F by design, and the right answer there is a separate higher-range valve rather than this one wound to its limit.

Check price on Amazon

No live price feed on this site, so we show none. #ad

Specifications above from Watts product page, LFMMV series lavatory and point-of-use mixing valves; First Supply listing, Watts LFMMV-M1-UT; Watts LFMMV installation instructions. We have not tested this unit ourselves.

What we judged these on

Mixing valves all look the same and all claim to do the same thing. What separates them is what the manufacturer is willing to publish, so that is what we ranked on:

  1. The adjustable outlet range, and where it stops. A valve that caps at 120°F cannot be misused. A valve that reaches 145°F can serve a fixture that genuinely needs hotter water. Those are different jobs.
  2. Minimum flow rate. The figure that decides whether a low-flow bathroom faucet still gets tempered water instead of a cold dribble. Only one of these three publishes it.
  3. Flow capacity at a stated pressure drop. "14 GPM at 50 psi" is a usable figure. "Up to 20 GPM" with no pressure drop attached is not.
  4. The required hot supply window. Every thermostatic valve needs a hot inlet hotter than its outlet setting. Publishing that window honestly is the difference between a valve that works and a valve that hunts.
  5. Standards listings. ASSE 1017 is the water-heater-outlet standard. ASSE 1069 and 1070 cover different applications and are worth having on the same body.
  6. Serviceability. Union connections, isolation, and whether you can pull the cartridge without cutting pipe.

We have not bench-tested these valves. Every number on this page is from the manufacturer's current specification sheet or product page, listed under the pick it belongs to and again at the foot of the page. How we pick.

The three standards, and why a valve carries all of them

Mixing valve listings look like alphabet soup. There are only three numbers that matter on a residential job, and they describe *where in the system* the valve is allowed to do its work.

What each ASSE listing covers
StandardWhat it coversWhy you care
ASSE 1017Temperature-actuated mixing valves for hot water source applications — i.e. at the water heater outletThis is the listing a whole-house valve at the tank needs
ASSE 1069Automatic temperature control valves for single-pipe tempered water systemsRelevant where one tempered line feeds a group of fixtures
ASSE 1070Water temperature limiting devices at individual or multiple fixturesThe point-of-use case: a lavatory, a bank of sinks
ASSE 1016Fixture-level anti-scald devices in showers and tub/shower valvesA tank valve does not replace this where code requires it

All three picks here are listed to 1017, 1069 and 1070, so any of them can sit at the tank or at a fixture group. None of them is an ASSE 1016 device, and Watts' own literature says plainly that its valve cannot by itself control final temperature where a 1016 or 1070 device is required. In practice: fit a mixing valve at the tank *and* leave the anti-scald cartridges in your shower valves alone.

The one number that decides whether it works

A thermostatic mixing valve needs a hot inlet hotter than the temperature you want out of it. There is no way around this; it is how the device functions. The HeatGuard publishes its window as a 120 to 180°F hot supply, which is the clearest statement of the rule any of these three makes.

Published specifications, side by side

From each manufacturer's current spec sheet or product page
Cash Acme HG110-DHoneywell AM-1 (AM101)Watts LFMMV-M1
Adjustable outlet85 - 130°F70 - 145°F (variant dependent)80 - 120°F
Factory setting115 - 120°FNot publishedNot published
Stated accuracyNot publishedNot published+/-3°F
Minimum flow0.5 GPMNot published0.5 GPM (low end of range)
Maximum flow14 GPM at 50 psiNot published12 GPM (capacity chart)
Maximum pressure230 psi150 psi150 psi
Hot supply window120 - 180°FRated to 212°FNot published
BodyLead-free DZR brassLead-free brassLead-free (material not stated)
ASSE listings1017, 1069, 10701017 class1017, 1069, 1070

Read that table as a document-quality comparison rather than a performance one. The HeatGuard is not necessarily a better valve than the Honeywell; it is a valve whose manufacturer tells you more about it, which on a part you are going to size and set yourself is worth something real.

Sizing: 3/4 inch, and why the minimum matters more than the maximum

For a whole-house valve on a standard residential tank, 3/4 inch is the size. Everything on this page is available in it. The interesting constraint is at the other end of the range.

  • Maximum flow only matters if your peak simultaneous draw exceeds it. A 14 GPM valve at a 50 psi drop comfortably covers two showers and a sink; whole-house demand in a family home rarely reaches it.
  • Minimum flow matters every day. Below the valve's minimum, the thermostatic element cannot modulate reliably, and what arrives at a trickling faucet may be colder or more variable than you expect. A 0.5 GPM minimum is low enough for a modern 1.2 GPM lavatory aerator; nothing on this page is low enough for a dripping tap.
  • Pressure drop is real. Every valve is a restriction. If your static pressure is already marginal, measure it before you add one. A pressure gauge on a hose bib costs very little. Expansion tank sizing explains how to take that reading, because you need the same number for the expansion tank.

Where it goes, and in what order

The valve sits on the hot outlet of the water heater, with a cold feed teed in from the cold supply. The hot it makes is the tempered water that goes to the house.

  1. Isolate and drain enough of the pipework to work on it. On a tank install this is usually done at the same time as the heater, which is the cheapest moment to do it.
  2. Fit unions or isolation valves on both inlets and the outlet. Every valve here is available with union ends for exactly this reason: a thermostatic cartridge is a wear part, and you do not want to cut pipe to change one in 2034.
  3. Respect the inlet markings. Hot, cold and tempered outlet are marked on the body, and a valve plumbed backwards does not fail obviously — it just never controls properly.
  4. Keep the inlet strainers. The HeatGuard has stainless screens on the inlets. They catch the debris that otherwise jams the piston, and they are the first thing to check if the valve stops controlling.
  5. Set it with a thermometer at the tap, not by the mark on the cap. Run the nearest fixture for two minutes first so you are reading delivered temperature rather than pipe contents.
  6. Then lock it. The HeatGuard's adjustment locks against being wound up past the setting, which is the detail that keeps a correct install correct after someone else lives there.

What it does for usable hot water

This is the under-sold half of the case. The usable hot water in a tank is not its capacity — it is how many gallons at delivery temperature you can get out of it before the blend goes cold. Store at 140°F and deliver at 120°F and every gallon drawn from the tank gets stretched with cold, so the same tank serves a longer shower sequence.

It does not change the first-hour rating on the label, and it is not a substitute for sizing the tank properly — first-hour rating, explained is still the number to buy on. But if you are two minutes short of a comfortable morning, a mixing valve is a far cheaper experiment than a new heater. Why your water heater runs out of hot water runs through the rest of the options.

When to skip it

  • You are leaving the tank at 120°F. Nothing to mix, no benefit.
  • Your heater is a tankless unit with an accurate setpoint. It already delivers the temperature you ask for; the bacteria argument that justifies hot storage does not apply because there is no storage. Tankless vs tank.
  • Your water is very hard and the valve would be unserviceable. Scale is what kills thermostatic elements. If you fit one on hard water, fit it with unions and expect to service it. Best water heaters for hard water.
  • You have a point-of-use heater under a sink. Those run at modest temperatures by design; a whole-house valve is the wrong tool. Are point-of-use water heaters worth it?

What goes in with it

A water heater is a system, not a box. These are the parts that go in with it, and the ones people discover they need halfway through the job.

  • Expansion tank

    Required by code on a closed system, which is most homes with a pressure-reducing valve.

  • Drain pan

    Cheap insurance anywhere the tank sits above something you care about.

  • Anode rod

    The part that decides when the tank leaks. Replacing it is the highest-value hour of maintenance there is.

So which one

Buy the HeatGuard HG110-D if you want the fullest published data and the highest pressure rating, and if the 130°F ceiling suits you — it is the valve we would fit on a 140°F tank in a normal house. Buy the Honeywell AM-1 if you need to deliver above 130°F somewhere, because it is the only one here whose range reaches 145°F. Buy the Watts LFMMV-M1 if holding a steady tap temperature is the point: it is the only one of the three that publishes an accuracy figure, and the union body makes it the easiest to service.

Whichever you pick, fit it at the same time as the rest of the install list. Water heater installation kit covers the four parts the box never includes, and a mixing valve is the one most often left off the quote.

Questions people actually ask

›Do I need a mixing valve on my water heater?
You need one if you want to store water above 120°F — the usual recommendation for bacterial control in a tank that sits unused — without delivering scalding water at the taps. If you are leaving the tank at 120°F, a mixing valve adds a restriction and a failure point for no benefit.
›What temperature should a water heater mixing valve be set to?
120°F at the fixture is the common target, and two of the three valves here cap at or near it: the Cash Acme HeatGuard is factory set to 115-120°F and the Watts LFMMV-M1 tops out at 120°F. Set it with a thermometer at the nearest tap after running it for two minutes, not by the mark on the cap.
›What size mixing valve do I need for a water heater?
3/4 inch for a whole-house valve on a standard residential tank. All three picks here are available in 3/4 inch, in sweat, threaded, CPVC, PEX and push-fit ends. The figure worth checking is the minimum flow rate rather than the maximum, because that is what decides whether a low-flow faucet still gets tempered water.
›What is the difference between ASSE 1017 and ASSE 1070?
ASSE 1017 covers temperature-actuated mixing valves at the hot water source, which is the water heater outlet. ASSE 1070 covers temperature limiting devices at individual or multiple fixtures. All three valves on this page carry both listings, along with ASSE 1069 for single-pipe tempered water systems.
›Does a mixing valve replace the anti-scald valve in my shower?
No. Watts' own installation literature states that its mixing valve cannot by itself control final temperature at fixtures where an ASSE 1016 or ASSE 1070 listed device is required. Fit a mixing valve at the tank and leave the pressure-balancing or thermostatic cartridges in the shower valves in place.
›Will a mixing valve give me more hot water?
Effectively, yes, provided you also raise the tank temperature. Storing at 140°F and delivering at 120°F means each gallon drawn from the tank is blended with cold, so the same tank serves a longer run of showers. It does not change the first-hour rating printed on the label.
›Where does a thermostatic mixing valve get installed?
On the hot outlet of the water heater, with a cold feed teed in from the cold supply, so the tempered outlet feeds the house. Fit unions or isolation valves on all three ports: the thermostatic element is a wear part and you do not want to cut pipe to replace it.
›How long do water heater mixing valves last?
The failure mode is scale and debris on the thermostatic element rather than the body, so lifespan tracks water chemistry. The practical answer is to fit it with unions, keep the inlet strainers, and treat a valve that no longer holds temperature as a cartridge job rather than a plumbing job.